Application Note
Application Note: 030061
NetStreams , DigiLinX, ControLinX, MediaLinX, SpeakerLinX and SwitchLinX are Trademarks of NetStreams LLC.
All rights reserved. Copyright © 2008 NetStreams.
main +1 512.977-9393 / fax +1 512.977.9398 3600 W. Parmer Lane, Ste. 100; Austin, TX 78727
Using the RTI XP-8 to Create Time Based Events in DigiLinX
In DigiLinX Dealer Setup 2.3, NetStreams has introduced a new method of controlling DigiLinX from a 3
rd
party control system called Serial2Command (S2C). S2C allows external control systems to
communicate with and control DigiLinX, enabling dealers to offer a more flexible solution for control to
end users.
The S2C driver runs on a ControLinX, or on a MediaLinX Pro slot configured as a ControLinX. S2C
changes the ControLinX from a device that controls other 3
rd
party sub-systems, to one that listens for
commands from other systems and directs DigiLinX to perform various actions such as selecting a zone,
selecting a source, adjusting audio volume, or triggering a macro. This capability also allows dealers to
use external clocks, such as the RTI XP-8 processor, to trigger time and event based macros inside
DigiLinX.
The RTI XP-8 is a high-end remote control processor for automating the operation of electronic systems
in homes and office buildings. The XP-8 has 8 sense inputs and 8 relay/trigger outputs, 8 RS-232 ports,
and 8 IR ports. In addition, the XP-8 interfaces with products like RTI’s RM-433 RF receiver to integrate
RF remotes like the RTI T4.
For the purpose of this application note, we have designed a simple DigiLinX and RTI network to illustrate
the examples. This network diagram shows the key equipment:
T4
SwitchLinX
ControLinX
XP-8 RM-433 RF
MediaLinX MediaLinX
RS-232
SpeakerLinX
SpeakerLinX
In this example, the DigiLinX system consists of two SpeakerLinX, two MediaLinX, and one ControLinX
connected to a SwitchLinX. The ControLinX is connected via RS-232 to the RTI XP-8, and the XP-8 is
connected to a RM-433 RF. You will need o use a Null Modem adapter or cable for RTI Processors. In
this application, you can use any RF-capable RTI remote, such as a T4.
-Cont’d-
Vista de pagina 0
1 2 3 4 5 6 7 8

Indice de contenidos

Pagina 1 - Application Note

  DigiLinX™ Application NoteApplication Note: 030061 NetStreams , DigiLinX, ControLinX, MediaLinX, Sp

Pagina 2

  DigiLinX™ Application NoteApplication Note: 030061 NetStreams , DigiLinX, ControLinX, MediaLinX, Sp

Pagina 3

  DigiLinX™ Application NoteApplication Note: 030061 NetStreams , DigiLinX, ControLinX, MediaLinX, Sp

Pagina 4

  DigiLinX™ Application NoteApplication Note: 030061 NetStreams , DigiLinX, ControLinX, MediaLinX, Sp

Pagina 5

  DigiLinX™ Application NoteApplication Note: 030061 NetStreams , DigiLinX, ControLinX, MediaLinX, Sp

Pagina 6

  DigiLinX™ Application NoteApplication Note: 030061 NetStreams , DigiLinX, ControLinX, MediaLinX, Sp

Pagina 7

  DigiLinX™ Application NoteApplication Note: 030061 NetStreams , DigiLinX, ControLinX, MediaLinX, Sp

Pagina 8

  DigiLinX™ Application NoteApplication Note: 030061 NetStreams , DigiLinX, ControLinX, MediaLinX, Sp

Comentarios a estos manuales

Sin comentarios