CHAPTER 7 | TROUBLESHOOTING
ALL EMITTERS BLINKING EVEN WHEN IR CODES ROUTED
If IR Passthrough is enabled in the XP-8 properties within Integration
Designer™, feedback/blinking emitters will blink regardless of whether
the IR codes being sent have been routed out a specic port. IR
Passthrough allows the trigger codes received from RTI controllers to
be passed through to the emitters, but this should not have any affect
on devices being controlled.